BP Series
BP
Specification
-
- Standard: IEC60947-2
- Voltage Ue: 110~380V
- Rated current In: 10.15.20.30.40.50.60.75.100A
- Pole: 1P 2P 3P
- Breaking capacity:
- Icu:
- 1P 110V/ 5kA (sym)
- 2P 220V/ 5kA (sym)
- 3P 220V/ 5kA (sym)
- Icu:
- Trip Unit: Thermal magnetic
Applications Home Circuit Panel Use
BPH
Specification
-
- Standard: IEC60947-2
- Voltage Ue: 110~380V
- Rated current In: 15.20.30.40.50.60.75.100A
- Pole: 1P 2P 3P
- Breaking capacity:
- Icu:
- 1P 110V/ 10kA (sym)
- 2P 220V/ 10kA (sym)
- 3P 220V/ 10kA (sym)
- Icu:
- Trip Unit: Thermal magnetic
Applications Home Circuit Panel Use
BKH
Specification
-
- Standard: IEC60947-2
- Voltage Ue: 110~380V
- Rated current In: 15.20.30.40.50.60.75.100A
- Pole: 1P 2P 3P
- Breaking capacity:
- Icu:
- 1P 110V/ 15kA (sym) 220V/10 kA (sym)
- 2P 220V/ 15kA (sym) 380V/10kA (sym)
- 3P 220V/ 15kA (sym) 380V/10kA (sym)
- Icu:
- Trip Unit: Thermal magnetic
Applications Home Circuit Panel Use
BL
Specification
-
- Standard: IEC60947-2
- Voltage Ue: 110~380V
- Rated current In: 15.20.30.40.50.60.75.100A
- Pole: 1P 2P 3P
- Breaking capacity:
Icu:
-
-
- 1P 110V/ 5kA (sym)
- 2P 220V/ 5kA (sym)
- 3P 220V/ 5kA (sym)
- Trip Unit: Thermal magnetic
-
Applications Home Circuit Panel Use
BLH
Specification
-
- Standard: IEC60947-2
- Voltage Ue: 110~380V
- Rated current In: 15.20.30.40.50A
- Pole: 1P 2P 3P
- Breaking capacity:
Icu:
-
-
- 1P 110V/ 10kA (sym)
- 2P 220V/ 10kA (sym)
- 3P 220V/ 10kA (sym)
- Trip Unit: Thermal magnetic
-
Applications Home Circuit Panel Use
BLS
Specification
-
- Standard: IEC60947-2
- Voltage Ue: 110~380V
- Rated current In: 60.75.100A
- Pole: 2P 3P
- Breaking capacity:
Icu:
-
-
- 2P 220V/ 10kA (sym)
- 3P 220V/ 10kA (sym)
- Trip Unit: Thermal magnetic
-
Applications Home Circuit Panel Use
BKL
Specification
-
- Standard: IEC60947-2
- Voltage Ue: 110~380V
- Rated current In: 15.20.30.40.50.60.75.100A
- Pole: 1P 2P 3P
- Breaking capacity:
Icu:
-
-
- 1P 110V/ 15kA (sym) 220V/ 10kA (sym)
- 2P 220V/ 15kA (sym) 380V/ 10kA (sym)
- 3P 220V/ 15kA (sym) 380V/ 10kA (sym)
- Trip Unit: Thermal magnetic
-
Applications Home Circuit Panel Use
BL Series - Earth Leakage Protection
BL-50L
Specification
-
- Standard: CNS 5422
- Voltage: 110~220V
- Current: 15.20.30.40.50A
- Pole: 1P2E, 2P2E
- Rated current sensitivity: 30.100.200.300.500mA
- Operating time: 0.1s
- Breaking capacity:Icu:
- 1P 110V/ 5kA (sym)
- 2P 220V/ 5kA (sym)
Applications
- Humid Work Place
BL-50UL
Specification
-
- Standard: CNS 5422
- Voltage: 110~220V
- Current: 15.20.30.40.50A
- Pole: 1P2E, 2P2E
- Rated current sensitivity: 30.100.200.300.500mA
- Operating time: 0.1s(high speed)
- Breaking capacity:Icu:
- 1P 110V/ 10kA (sym) 220V/5 kA (sym)
- 2P 220V/ 10kA (sym)
Applications
- Humid Work Place
BLP-50L
Specification
-
- Standard: CNS 5422
- Voltage: 110~220V
- Current: 15.20.30.40.50A
- Pole: 1P2E, 2P2E
- Rated current sensitivity: 30mA
- Operating time: 0.1s
- Breaking capacity:Icu:
- 1P 110V/ 5kA (sym)
- 2P 220V/ 5kA (sym)
Applications
- Humid Work Place
BLP-50UL
Specification
-
- Standard: CNS 5422
- Voltage: 110~220V
- Current: 15.20.30.40.50A
- Pole: 1P2E, 2P2E
- Rated current sensitivity: 30mA
- Operating time: 0.1s
- Breaking capacity:Icu:
- 1P 110V/ 10kA (sym) 220V/5 kA (sym)
- 2P 220V/ 10kA (sym)
Applications
- Humid Work Place
BL-50F
Specification
-
- Standard: CNS 5422
- Voltage: 110~220V
- Current: 15.20.30.40.50A
- Pole: 2P1E, 2P2E
- Rated current sensitivity: 30mA
- Operating time: 0.1s
- Breaking capacity:Icu:
- 2P1E 110V/ 5kA (sym)
- 2P2E 220V/ 5kA (sym)
Applications
- Humid Work Place
BL-50U
Specification
-
- Standard: CNS 5422
- Voltage: 110V
- Current: 15.20.30.40.50A
- Pole: 2P1E
- Rated current sensitivity: 30mA
- Operating time: 0.1s
- Breaking capacity:Icu:
- 110V/ 10kA (sym)
Applications
- Humid Work Place
BL-100U
Specification
-
- Standard: CNS 5422
- Voltage: 110~220V
- Current: 15.20.30.40.50.60.75.100A
- Pole: 2P2E
- Rated current sensitivity: 30mA
- Operating time: 0.1s(high speed)
- Breaking capacity:Icu:
- 220V/ 10kA (sym)
Applications
- Humid Work Place
BL-50H
Specification
-
- Standard: CNS 5422
- Voltage: 110~220V
- Current: 15.20.30.40.50A
- Pole: 2P1E, 2P2E
- Rated current sensitivity: 30mA
- Operating time: 0.1s
- Breaking capacity:Icu:
- 2P1E 110V/ 15kA (sym) , 220V/ 10kA (sym)
- 2P2E 220V/ 5kA (sym)
Applications
- Humid Work Place
BL-KLF
Specification
-
- Standard: CNS 5422
- Voltage: 110~220V
- Current: 15.20.30 A
- Pole: 2P1E, 2P2E
- Rated current sensitivity: 30mA
- Operating time: 0.1s
- Breaking capacity:Icu:
- 2P1E 110~220V/ 1.5kA (sym)
- 2P2E 110~220V/ 1.5KA (sym)
Applications
- Humid Work Place
BL-K30F
Specification
-
- Standard: CNS 5422
- Voltage: 110~220V. 380~440V
- Current: 15.20.30 A
- Pole: 3P
- Rated current sensitivity: 30mA
- Operating time: 0.1s
- Breaking capacity:Icu:
- 3P 110~220V/ 1.5kA (sym)
- 3P 380~440V/ 1.5KA (sym)
Applications
- Humid Work Place
BL-BF
Specification
-
- Standard: CNS 5422
- Voltage: 110~220V
- Current: 30A(15A.20A)40A(15A.20A.30A)
- Pole: 2P
- Rated current sensitivity: 30mA
- Operating time: 0.1s
- Breaking capacity:Icu:
- 110~220V/ 1.5kA
- 110~220V/ 2.5kA (40A)
Applications
- Humid Work Place
BHA (MCB)
Specification
-
- Standard: IEC60947-2, IEC60898, GB10963
- Rated insulation voltage Ui: AC 690V
- Rated voltage: AC 230/400V, DC125V
- Rated current In:1.2.3.4.5.6.10.16.20.25.32.40.50.63A
- Pole: AC – 1P 2P 3P 4P , DC – 1P 2P
- Breaking capacity: AC – 4.5/6/10kA , DC – 10kA
- C/D TYPE
- AL.AX.SHT.UVT.OVT
Applications
-
- Home & Factoy Use
- Circuit Protection
BHR-A (RCCB)
- Test button(yellow) provides earth-leakage testing function during the regular maintenance.
- Tool-free installation with the application of standard DIN-rail TH35mm, makes installation easy and convenient.
- AC class: Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
- A class: Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase.
Standard: IEC61008-1Rated Current (In): 25, 32, 40, 63APole: 2P, 4PRated Voltage (V): 240Vac(2P), 415Vac(4P)Rated Sensitivity Current: 10/30/100/300 mARated limited short circuit current: 10kAResidual Current Type: A, ACEarth leakage protection
BHZ
With over and under voltage protection, the device will trip when the voltage supply is over or under value. If the voltage supply return to normal, the device will automatically reset without any manual intervention.High voltage detection accuracy and precision operating time using microcontroller, reliable protection .Using magnetic latching relay as internal part, energy conservation and environmental protection with low power consumption under normal operation.Rated Current (In): 25A, 32A, 40A, 50A, 63ARated Voltage (V): AC230V, 50HzPoles: 1P+NRated insulation voltage: 690VacRated impulse withstand voltage: 40,000V Voltage protection range: AC 0~450VOver/Under Voltage Protection
BHL
Specification
-
- Standard: IEC61009
- Rated insulation voltage Ui: AC 690V
- Rated voltage: AC 230/400V
- Rated current In:1.2.3.4.5.6.10.16.20.25.32.40.50.63A
- Pole: 1P 1P+N 2P 3P 4P
- Breaking capacity: 4.5/6/10kA
- C/D TYPE
- AL.AX.SHT.UVT.OVT
Applications
-
- Home & Factoy Use
- Circuit Protection
BHG
Specification
-
- Standard: IEC60947-3
- Rated voltage: AC 230/400VRated current In: 32.40.63.80.100A
- Pole: 1P 2P 3P 4P
Applications
-
- Home & Factoy Use
- Circuit Protection
BHL-A (RCBO)
- Excellent anti-electromagnetic interference capability which avoid the fault trip caused by a transient over-voltage.
- Tool-free installation with the application of standard DIN-rail TH35mm, makes installation easy and convenient.
- Reliable usage with N phase breakpoint.
- Electronic type A/AC type leakage protection.
- AC class: Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
- A class: Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase.
Rated Current (In): 6, 10, 16, 20, 25, 32, 40, 50, 63ARated Voltage (V): AC230V, 50/60HzPole: 1P+NRated limited short circuit current: 4.5 / 6 kARated Sensitivity Current: 30/100/300 mAResidual Current Type: A, ACOverload protectionShort circuit protectionEarthleakage protection
BHN
Specification
-
- Standard: IEC60947-2, IEC60898, GB10963
- Rated insulation voltage Ui: AC 690V
- Rated voltage: AC 230V
- Rated current In:1.2.3.4.5.6.10.16.20.25.32.40.50.63A
- Pole: AC – 1+N
- Breaking capacity: AC – 4.5/6kA
- C TYPE
Applications
-
- Home & Factoy Use
- Circuit Protection
Accessories
Specification
BHK1: Alarm Switch (AL) – 1NO 1NC // 230V 6A, 440V 3ABHK2: Auxiliary Contact (AX) – 1NO 1NC // 230V 6A, 440V 3ABHK3: Shunt Trip (SHT) – 1NO 1NC // 230V 6A, 440V 3A // AC12V/24~48V/230~415V, DC12V/12~48V/110~130VBHK4: Under Voltage Trip (UVT) – 1NO 1NC // 230V 6A, 440V 3A // AC220~240V, DC48VBHK5: Over Voltage Trip (OVT) – Rated voltage 230V // 15mA // over voltage range 280V +-5% // trip time 0.25ms
Applications
-
- Home & Factoy Use
- Circuit Protection
RPC (MCB)
Features
-
- Overload and instantaneous protection
- Comply with IEC 60898-1 and IEC 60947-2
- Window display for ON/OFF status
- Din-rail TH35mm tool free installation
Specification
-
- Standard: IEC60947-2, IEC60898
- Rated Current: 6, 10, 16, 20, 25, 32, 40, 50, 63A
- Pole: 1P, 2P, 3P, 4P
Breaking Capacity
Protection
-
- Overload protection
- Short circuit protection
RPV (RCCB)
Features
-
- Leakage protection
- Comply with IEC 61008-1
- Window display for ON/OFF status and leakage indicator
- Leakage test bottom
- Din-rail TH35mm tool free installation
Specification
-
- Standard: IEC61008-1
- Rated Current: 16, 20, 25, 32, 40, 63A
- Rated Sensitivity Current: 10, 15, 30, 100, 300mA
- Pole: 2P, 4P
- Residual Current Type: A, AC
Breaking Capacity
Protection
Earth leakage protection
RPL (RCBO)
Features
-
- Overload, instantaneous and leakage protection
- Comply with IEC 61009-1
- Window display for leakage indicator
- Leakage test bottom
- Din-rail TH35mm tool free installation
Specification
-
- Standard: IEC61009
- Rated Current: 6, 10, 16, 20, 25, 32, 40, 50, 63A
- Rated Sensitivity Current:10, 15, 30, 100, 300mA
- Pole: 1P+N
- Residual Current Type: A, AC
Breaking Capacity
Protection
-
- Overload protection
- Short circuit protection
- Earthleakage protection
BL-BF V
Stantard: IEC 61008-1Product type: RCCBRated breaking capacity: 1.5kAPole: 2P0ERated voltage: AC110V~AC240VResidual current type: ACRated sensitivity current: 15, 30mA
Earth leakage protection
BL-BF L
Stantard: IEC 61009-1Product type: RCBORated breaking capacity: 2kAPole: 2P2ERated voltage: AC110V~AC240VResidual current type: ACRated sensitivity current: 15, 30mA
Earth leakage with overload protection
BL-BF C
Stantard: IEC 60947-2Product type: MCBRated breaking capacity: 1.5kAPole: 2P1ERated voltage: AC240VOverload protectionShort circuit protection